Skip to Content

1.800.661.4591

Request a Quote Online Training

Nuclear Medicine / Detectors

Alpha

Model 43-1
Alpha Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 83 cm2 (12.9 in2)
  • Efficiency: 239Pu : 33%
Model 43-2
Alpha Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 9.7 cm2 (1.5 in2)
  • Efficiency: 
    239Pu : 30%
    230Th : 30%
Model 43-202
Alpha Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 17.8 cm2 (2.8 in2)
  • Efficiency: 239Pu : 18%
Model 43-5
Alpha Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 76 cm2 (11.9 in2)
  • Efficiency: 239Pu : 13%
Model 43-65
Alpha Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 63 cm2 (9.8 in2)
  • Efficiency:
    • 239Pu : 17%
    • 230Th : 17%
Model 43-90
Alpha Scintillation Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 125 cm2 (19.4 in2)
  • Efficiency: 239Pu : 20%
Model 43-92
Alpha Scintillation Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 100 cm2 (15.5 in2)
  • Efficiency: 239Pu : 20%
Model 43-136
Alpha Detector
  • Detector Type: ZnS(Ag) Scintillator
  • Active Window Area: 65.3 cm2 (10.1 in2)
  • Efficiency: ²³⁹Pu : 20%
Model 43-44
Alpha Detector
  • Air Proportional
  • 76 cm2 (11.8 in2)
  • 239Pu : 8%
Model 43-44-1
Alpha Detector
  • Detector Type: Air Proportional
  • Active Window Area: 154 cm2 (23.9 in2)
  • Efficiency: 239Pu : 8%

Alpha-Beta Detectors

Model 43-1-1
Alpha-Beta Detector
  • Detector Type: ZnS(Ag) + Plastic Scintillator
  • Active Window Area: 83 cm2 (12.9 in2)
  • Efficiency:
    • 239Pu : 30%
    • 90Sr/90Y : 30%
    • 14C : 4%
Model 43-2-2
 Alpha-Beta Detector
  • Detector Type: ZnS(Ag) + Plastic Scintillator
  • Active Window Area: 9.7 cm2 (1.5 in2)
  • Efficiency:
    • 239Pu : 25%
    • 90Sr/90Y : 20%
    • 14C : 5%
Model 43-65-2
Alpha-Beta Detector
  • Detector Type: ZnS(Ag) + Plastic Scintillator
  • Active Window Area: 63 cm2 (9.8 in2)
  • Efficiency:
    • 230Th : 20%
    • 239Pu : 20%
    • 99Tc : 15%
    • 90Sr/90Y : 20%
    • 14C : 1%
Model 43-89
Alpha-Beta Scintillation Detector
  • Detector Type: ZnS(Ag) + Plastic Scintillator
  • Active Window Area: 63 cm2 (9.8 in2)
  • Efficiency:
    • 230Th : 20%
    • 239Pu : 20%
    • 99Tc : 15%
    • 90Sr/90Y : 20%
    • 14C : 1%
Model 43-93
Alpha-Beta Scintillation Detector
  • Detector Type: ZnS(Ag) + Plastic Scintillator
  • Active Window Area: 100 cm2 (15.5 in2)
  • Efficiency:
    • 239Pu : 20%
    • 99Tc : 15%
    • 90Sr/90Y : 20%
Model 43-147
Alpha-Beta Scintillation Detector
  • Detector Type: ZnS(Ag) + Plastic Scintillator
  • Active Window Area: 200 cm2 (31.0 in2)
  • Efficiency:
    • 239Pu : 20%
    • 99Tc : 13%
    • 90Sr/90Y : 20%
Model 43-68
Alpha-Beta Scintillation Detector
  • Detector Type: Rechargable Gas Proportional
  • Active Window Area: 126 cm2 (19.5 in2)
  • Efficiency:
    • 239Pu : 20% 
    • 14C : 15%
    •  99Tc : 30%
    •  90Sr/90Y : 20%
    • Gamma : 1%
Model 43-143-1
Alpha-Beta Detector
  • Detector Type: Gas Proportional
  • Active Window Area: 100 cm2 (15.5 in2)
  • Efficiency:
    • 239Pu : 20% 
    • 14C : 15%
    • 90Sr/90Y : 20%
    • Gamma: 1%
Model 43-37 Series
Alpha-Beta Gas Proportional Detector
  • Detector Type: Gas Proportional
  • Active Window Area: 100 cm2 (15.5 in2)
  • Efficiency:
    • Gross Counting

      • 239Pu : 20%
        99Tc : 30%
        90Sr/90Y : 30%
        Gamma 1% 

         

    • Alpha-Beta Counting

      • 239Pu : 17.5%
        99Tc : 20%
        90Sr/90Y : 20%
        Gamma 1% 

Model 43-135-1
Large Area 2π Proportional Detector
  • Detector Type: Gas Proportional For Large-Area Source Calibration
  • Active Window Area: 500 cm2 (77.4 in2) Windowless
  • Efficiency:
    • 239Pu : 42%
    • 230Th : 33%
    • 99Tc : 55%
    • 63Ni : 37%
    • 90Sr/90Y : 55%

Alpha-Beta-Gamma Detectors

Model 44-7
Alpha-Beta-Gamma Detector
  • Detector Type: End Window GM
  • Active Window Area: 6 cm2 (0.93 in2)
  • Efficiency: 2100 cpm per mR/hr (137Cs)

 

Model 44-9 Alpha-Beta-Gamma Detector

The GM pancake-type detector in the Model 44-9 is one of the most popular radiation detectors used throughout the world. This alpha, beta, and gamma radiation detector has a rugged metal housing and is conveniently shaped and sized for checking contamination on people and objects.

Model 44-9DOSE
Alpha-Beta-Gamma Detector with Dose Filter
  • Detector Type: Pancake GM
  • Active Window Area: 15.5 cm2 (2.4 in2)
  • Efficiency: 3300 cpm per mR/hr (137Cs)
Model 44-9-18
Extended Reach Alpha-Beta-Gamma Detector
  • Detector Type: Pancake GM
  • Active Window Area: 15.5 cm2 (2.4 in2)
  • Efficiency: 3300 cpm per mR/hr (137Cs)
Model 44-40 Series
Shielded Alpha-Beta-Gamma Detector
  • Detector Type: Pancake GM With Lead Shielding
  • Active Window Area: 15.5 cm2 (2.4 in2)
  • Efficiency: 3300 cpm per mR/hr (137Cs)
Model 44-88
Alpha-Beta-Gamma Detector
  • Detector Type: Pancake GM
  • Active Window Area: 15. cm2 (2. in2)
  • Efficiency: 3300 cpm per mR/hr (137Cs)
Model 44-89
Alpha-Beta-Gamma Detector
  • Detector Type: 4 Pancake GMs
  • Active Window Area: 62 cm2 (9.6 in2)
  • Efficiency: 13,200 cpm per mR/hr (137Cs)
Model 44-94
Alpha-Beta-Gamma Detector
  • Detector Type: 4 Pancake GMs
  • Active Window Area: 62 cm2 (9.6 in2)
  • Efficiency: 13,200 cpm per mR/hr (137Cs)
Model 44-25
Alpha-Beta-Gamma Hand Monitor Detector
  • Detector Type: 2 Pancake GMs Hand Monitor Detector 
  • Active Window Area: 31 cm2 (4.8 in2)
  • Efficiency: 6600 cpm per mR/hr (137Cs)
Model 44-26
Alpha-Beta-Gamma Foot Monitor Detector
  • Detector Type: 3 Pancake GMs Foot Monitor Detector 
  • Active Window Area: 46 cm2 (7.1 in2)
  • Efficiency: 9900 cpm per mR/hr (137Cs)

     

Beta Detectors

Model 44-1
Beta Detector
  • Detector Type: Plastic Scintillator For Beta Detection
  • Active Window Area: 9.7 cm2 (1.5 in2)
  • Efficiency: 14C : 7%
Model 44-21
Beta-Gamma Detector
  • Detector Type: NaI(Tl) + Plastic Scintillator For Beta-Gamma Detection
  • Active Window Area: 5.1 cm2 (0.8 in2)
  • Efficiency:
    • 14C : 4%
    • 32P : 28% 
    • 125I : 38%
    • 129I : 19%
Model 44-98
Beta-Gamma Detector
  • Detector Type: NaI(Tl) + Plastic Scintillator For Beta-Gamma Detection
  • Active Window Area: 5 cm2 (0.8 in2)
  • Efficiency: 
    • 125I : 15%
    • 129I : 8%
    • 14C : 3%
Model 43-65-1
Beta Detector
  • Detector Type: Plastic Scintillator For Beta-Gamma Detection
  • Active Window Area: 63 cm2 (9.8 in2)
  • Efficiency:
    • 99Tc : 15%
    • 90Sr/90Y : 20%
    • 14C : 1%
Model 44-116
Beta Scintillation Detector
  • Detector Type: Plastic Scintillator For Beta-Gamma Detection
  • Active Window Area:125 cm2 (19.4 in2
  • Efficiency:
    • 14C : 4% 
    • 90Sr/90Y : 30%
    • 99Tc : 20%
Model 44-142
Beta Scintillation Detector
  • Detector Type: Plastic Scintillator For Beta Detection
  • Active Window Area:100 cm2 (15.5 in2)
  • Efficiency:
    • 14C : 4% 
    • 90Sr/90Y : 30%
    • 99Tc : 20%
Model 44-215
Angled Beta Detector
  • Detector Type: Plastic Scintillator For Beta Detection
  • Active Window Area: 20 cm2 (3.1 in2)
  • Efficiency: 
    • 99Tc : 33%
    • 14C : 10%
    • 90Sr/90Y : 33%
Model 44-92
Beta-Gamma Detector
  • Detector Type: Gas Proportional For Beta/Gamma Detection
  • Active Window Area: 126 cm2 (19.5 in2)
  • Efficiency:
    • 14C : 10%
    • 99Tc : 13%
    • 36Cl : 24%
    • 90Sr/90Y : 26%
    • 129I : 3%
    • 57Co : 1.6%
    • 55Fe : 1.2%
    • 239Pu : 10%
Model 44-110
Large Area Tritium Detector
  • Detector Type: Windowless Gas Flow Proportional For Tritium/Beta Detection
  • Active Window Area: 126 cm2 (19.5 in2)
  • Efficiency: 3H : 25%

Gamma GM Detectors

Model 133 Series
Gamma Detector
  • Detector Type: Energy-Compensated GM
  • Sensitivity (Cs-137): 
    • 133-2:1000 cpm per mR/hr

    • 133-3: 450 cpm per mR/hr

    • 133-4: 100 cpm per mR/hr

    • 133-6: 18 cpm per mR/hr

  • Linear Range (w/o DTC)
    • 133-2: 0.1 to 200 mR/hr

    • 133-3: 0.1 mR/hr to 1 R/hr

    • 133-4: 1 mR/hr to 2 R/hr

    • 133-6: 4 mR/hr to 6 R/hr

    • 133-7: 25 mR/hr to 30 R/hr

 

Model 44-6
Beta-Gamma Detector
  • Detector Type: GM with Beta Window
  • Sensitivity (Cs-137): 1200 cpm per mR/hr
  • Linear Range: ±10% up to 50 mR/hr
Model 44-38
Beta-Gamma Detector
  • Detector Type: GM with Beta Window
  • Sensitivity (Cs-137): 1200 cpm per mR/hr
  • Linear Range: ±10% up to 50 mR/hr
Model 44-150 Series
High-Sensitivity Gamma Detector
  • Detector Type: Energy-Compensated GM
  • Sensitivity (Cs-137): 1200 cpm per mR/hr
  • Linear Range: ±10% up to 50 mR/hr
Model 44-183
Shielded Gamma Detector
  • Detector Type: Energy-Compensated GM
  • Sensitivity (Cs-137): 
    • 44-150-1:
      4000 cpm per mR/hr
    • 44-150-3:
      13,500 cpm per mR/hr
  • Linear Range:
    • 44-150-1:
      0.1 to 50 mR/hr

    • 44-150-3:
      0.01 to 8 mR/hr

 

Gamma Scintillator Detectors

Model 44-2
Gamma Detector
  • Detector Type: NaI(Tl) Scintillator 2.5 x 2.5 cm (1 in. x 1 in.)
  • Sensitivity (Cs-137): 175 cpm per µR/hr (137Cs)
  • Efficiency:
    • 125I : 7%

    • 57Co : 10%

    • 137Cs : 3%

    • 60Co : 3%

Model 44-10
Gamma Detector
  • Detector Type: NaI(Tl) Scintillator 5.1 x 5.1 cm (2 x 2 in.)
  • Sensitivity (Cs-137): 900 cpm per µR/hr (137Cs)
  • Efficiency:
    • 125I : 4%
    • 57Co : 20%
    • 137Cs : 9%
    • 60Co : 15%
Model 44-62
Gamma Detector
  • Detector Type: NaI(Tl) Scintillator 1.3 x 2.5 cm (0.5 x 1 in)
  • Sensitivity (Cs-137): 49 cpm per μR/hr (137Cs)

 

Model 44-11
Gamma Detector
  • Detector Type: NaI(Tl) Scintillator 5.1 x 5.1 cm (2 x 2 in.)
  • Sensitivity (Cs-137): 900 cpm per µR/hr (137Cs)
Model 44-20
Gamma Detector
  • Detector Type: NaI(Tl) Scintillator 7.6 x 7.6 cm (3 x 3 in.)
  • Sensitivity (Cs-137): 2300 cpm per μR/hr (137Cs)
  • Efficiency: 125I : 29%
Model 44-159-1
Csl Scintillator Detector
  • Detector Type: 18 x 18 mm (0.7 x 0.7 in.)
  • Sensitivity (Cs-137): 2300 cpm per μR/hr (137Cs)
  • Efficiency: 120 cpm per µR/hr
Model 44-132
Gamma Scintillator Detector
  • Detector Type: Plastic Scintillator 14.6 x 2.5 cm (5.75 x 1 in.)
  • Sensitivity (Cs-137): 1500 cpm per µR/hr

Low-Energy Gamma Scintillator Detectors

Model 44-3
Gamma Detector
  • Detector Type: NaI(Tl) Scintillator 2.5 x 0.1 cm (1 x 0.04 in.)
  • Active Window Area: 5 cm2 (0.8 in2)
  • Energy Range: 10 to 60 keV
Model 44-172
Gamma Detector
  • Detector Type: YSO Scintillator
  • Active Window Area: 5 cm2 (0.8 in2)
Model 44-17
Gamma Detector
  • Detector Type: NaI(Tl) Scintillator 5.1 x 0.2 cm (2 x 0.08 in.)
  • Active Window Area: 17.8 cm2 (2.8 in2)
  • Energy Range: 10 to 200 keV
Model 44-213
FIDLER Low-Energy Gamma Detector
  • Detector Type: CsI Scintillator 12.7 x 0.12 cm (5 x 0.05 in.)
  • Active Window Area: 127 cm2(10.6 in2)
  • Energy Range: 10–200 keV

Neutron Detectors

Model 42-49 Series
Neutron Detector
  • Detector Type:
    • 3He Tube
    • Moderator: 19.5 cm (7.7 in.) dia.
  • Sensitivity (241Am/Be):
    • 42-49: 10 cpm per µSv/h (100 cpm per mrem/hr)
    • 42-49B: 4.5 cpm µSv/h (45 cpm per mrem/hr)
    • 42-49B-1: 7.6 cpm per µSv/h (76 cpm per mrem/hr)
  • Detection Range: Thermal to 12 MeV
Model 42-30H
Neutron Detector
  • Detector Type:
    • 3He Tube
    • Moderator: 25.4 cm (10 in.) dia.
  • Sensitivity (241Am/Be):
    • 20,000 cpm per mSv/h (200 cpm per mrem/hr)
  • Detection Range: Thermal to 12 MeV
Model 42-31H
Neutron Detector
  • Detector Type:
    • 3He tube
    • Moderator: 22.9 cm (9 in.) dia
  • Sensitivity (241Am/Be):
    • 10,000 cpm per mSv/h (100 cpm per mrem/hr )
  • Detection Range: Thermal to 12 MeV
Model 42-5
Neutron Ball Cart and Detector
  • Detector Type: 6LiI Scintillator
  • Sensitivity (241Am/Be): 45 cpm per mrem/hr
  • Detection Range: Thermal to 12 MeV

 

Model 42-41L
Neutron Detector
  • Detector Type: PRESCILA Proton Recoil Scintillator
  • Sensitivity (241Am/Be): 350 cpm per mrem/hr
  • Detection Range: Thermal to 100 MeV
Model 42-38
WENDI-2 Wide Energy Neutron Detector
  • Detector Type:
    • 3He Tube
    • Moderator: 22.9 cm (9 in.) dia.
  • Sensitivity (241Am/Be): 450 cpm per mrem/hr
  • Detection Range: Thermal to 5 GeV

Waterproof Detectors

Model 9-7
High Range Ion Chamber Survey Meter
  • Digital Meter
  • Display Range: 0 to 19.99 kR/hr
  • 3 Available Detectors
  • Replacement for Eberline Model RO-7
Model 44-2-14
Waterproof Gamma Scintillator Detector
  • Description: 
    • 2.5 x 2.5 cm (1 x 1 in.) NaI(Tl) Scintillator Aluminum Housing Hard-Wired 3 m (10 ft.) Cable
    • Submersible up to 30 m (100 ft)
  • Part Number: 47-2473
Model 44-2-23
Waterproof Gamma Scintillator Detector
  • Description: 
    • 2.5 x 2.5 cm (1 x 1 in.) NaI(Tl) Scintillator Aluminum Housing Hard-Wired 3 m (10 ft.) Cable
    • Submersible up to 30 m (100 ft)
  • Part Number: 47-3656
Model 44-10-5
Waterproof Gamma Scintillator Detector
  • Description: 
    • 5.1 x 5.1 cm (2 x 2 in.) NaI(Tl) Scintillator Stainless Steel Housing Hard-Wired 3 m (10 ft.) Cable
    • Submersible up to 30 m (100 ft)
  • Part Number: 47-2427
Model 133 Series
Gamma Detector
  • Detector Type: Energy-Compensated GM
  • Sensitivity (Cs-137): 
    • 133-2:1000 cpm per mR/hr

    • 133-3: 450 cpm per mR/hr

    • 133-4: 100 cpm per mR/hr

    • 133-6: 18 cpm per mR/hr

  • Linear Range (w/o DTC)
    • 133-2: 0.1 to 200 mR/hr

    • 133-3: 0.1 mR/hr to 1 R/hr

    • 133-4: 1 mR/hr to 2 R/hr

    • 133-6: 4 mR/hr to 6 R/hr

    • 133-7: 25 mR/hr to 30 R/hr

 

Sample Counter Heads

Model 43-9
Alpha Sample Counter Head
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 2.5  x 0.15 cm (1 x 0.06 in.) [D x L]
  • Efficiency: 230Th : 30%
Model 43-10
Alpha Sample Counter Head
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
  • Efficiency: 230Th : 37%
Model 43-78
Alpha Sample Counter Head
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 12.7 x 0.46 cm (5 x 0.18 in.) [D x L]
  • Efficiency: 230Th : 37% 239Pu : 37%
Model 43-10-1
Alpha Sample Counter Head
  • Alpha-Beta ZnS(Ag) + Plastic Scintillator
  • Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
  • Efficiency:
    • 239Pu : 37%
    • 230Th : 32%
    • 238U : 39%
    • 14C : 5%
    • 99Tc : 27%
    • 137Cs : 29%
    • 99Sr/90Y : 26%
Model 43-10-10
Alpha-Beta Sample Counter Head for iCam/Harwell Filters
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
  • Efficiency:
    • 239Pu : 37%
    • 230Th : 32%
    • 238U : 39%
    • 14C : 5%
    • 99Tc : 27%
    • 137Cs : 29%
    • 99Sr/90Y : 26%
Model 43-78-2
Alpha-Beta Sample Counter Head for iCam/Harwell Filters
  • Detector Type: Alpha-Beta ZnS(Ag) + Plastic Scintillator
  • Max. Sample Size: 5.1 x 1.0 cm (2 x 0.4 in.) [D x L] Adapted for iCam Filters
  • Efficiency: 239Pu : 40%
Model 44-110-4
Windowless Sample Counter Detector
  • Detector Type: Alpha-Beta Windowless Gas Flow Proportional
  • Max. Sample Size: 5.1 x 0.9 cm (2.0 x 0.4 in.) [D x L]
  • Efficiency:
    • 3H : 3%
    • 14C : 21%
    • 63Ni : 36%
    • 239Pu : 42%
Model 120
Alpha-Beta-Gamma Sample Counter
  • Detector Type: Alpha-Beta ZnS(Ag) + Plastic Scintillator
  • Max. Sample Size: 5.1 x 1.0 cm (2 x 0.4 in.) [D x L] Adapted for iCam Filters
  • Efficiency: 239Pu : 40%
Model 180-8
Shielded Sample Holder with Detector
  • Detector Type: Alpha-Beta-Gamma End Window GM
  • Max. Sample Size: 5.1 cm (2 in.) dia.
  • Efficiency:
    • 14C : 2%
    • 90Sr/90Y : 10%
    • 239Pu : 7%
Model 43-78-1
Beta Sample Counter Head
  • Detector Type: Beta Plastic Scintillator
  • Max. Sample Size: 12.7 x 0.46 cm (5 x 0.18 in.) [D x L]
  • Efficiency:
    • 90Sr/90Y : 40%
    • 14C : 12%
    • 99Tc : 35%
Model 203
Shielded Well Gamma Sample Counter Head
  • Detector Type: Gamma NaI(Tl) Well Scintillator 5.1 x 4.6 cm (2 x 1.8 in.) [D x L]
  • Max. Sample Size: 1.7  x 3.9 cm (0.66 x 1.6 in.) [D x L]
  • Efficiency:
    • 129I : 65%
    • 137Cs : 33%
    • 60C0 : 43%
Model 243
Shielded Well Gamma Sample Counter Head
  • Detector Type: Gamma NaI(Tl) Integral Line Well Scintillator 4.6 x 5.1 cm (1.8 x 2 in.) [D x L]
  • Active Window Area: 1.7 x 3.9 cm (0.66 x 1.6 in.) [D x L]
  • Efficiency:
    • 125I : 80%
    • 99mTc : 90%
    • 137C : 33%
    • 60Co : 43%
Model 182
Radon Flask Sample Holder Head
  • Detector Type: For Radon Flask Sample Counting
  • Active Window Area: 6.1 x 12.7 cm (2.4 x 5 in.) [D x L]

Sample Holders

Model 180-1
Sample Holder for 5.1 cm (2 in.) OD Detectors
  • Max Sample Size: 5.1cm (2 in.) dia.
  • Features: Compatible with all 5.1 cm (2 in.) OD detectors, including: Model 43-2, Model 43-2-2, Model 44-1, Model 44-2, Model 44-3, Model 44-21, Model 44-98
Model 180-1L
Shielded Sample Holder for 5.1 cm (2 in.) OD Detectors
  • Max. Sample Size: 5.1cm (2 in.) dia.
  • Features: Lead Shielding - compatible with all 5.1 cm (2 in.) OD detectors, including: Model 43-2, Model 43-2-2, Model 44-1, Model 44-2, Model 44-3, Model 44-21, Model 44-98
Model 180-24
Sample Holder for 5.1 cm (2 in.) OD Detectors
  • Max. Sample Size: 5.1 cm (2 in.) dia.
  • Features: Compatible with all 5.1 cm (2 in.) OD detectors, including: Model 43-2, Model 43-2-2, Model 44-1, Model 44-2, Model 44-3, Model 44-21, Model 44-98
Model 180-7
Sample Holder for 6.6 cm (2.6 in.) OD Detectors
  • Max. Sample Size: 5.1 cm (2 in.) dia.
  • Features: Compatible with all 6.6 cm (2.6 in.) OD detectors, including: Model 44-10, Model 44-17
Model 180-16
Sample Holder for Models 43-1, 43-1-1
  • Max. Sample Size: 10.2 cm (4 in.) dia.
  • Features: Compatible with Model 43-1, 43-1-1
Model 180-4
Sample Holder for Model 44-7
  • Max. Sample Size: 10.2 cm (4 in.) dia.
  • Features: Compatible with Model 43-1, 43-1-1
Model 180-2
Sample Holder for Model 44-9
  • Max Sample Size: 5.1 cm (2 in.) dia.
  • Features: Compatible with Model 44-9
Model 180-15
Sample Holder for Model 44-40
  • Max Sample Size: 5.1 cm (2 in.) dia.
  • Features: Compatible with Model 44-9
Model 180-15-3
Sample Holder for Models 43-92, 43-93, 43-142
  • Max Sample Size: 5.1 x 1.5 cm (2 x 0.6 in.) [D x L]
  • Features: Compatible with Model 43-92, Model 43-93, Model 44-142
Model 180-8
Shielded Sample Holder with Detector
  • Detector Type: Alpha-Beta-Gamma End Window GM
  • Max. Sample Size: 5.1 cm (2 in.) dia.
  • Efficiency:
    • 14C : 2%
    • 90Sr/90Y : 10%
    • 239Pu : 7%
Model 180-9
Shielded Sample Holder
  • Max Sample Size: 5.1 cm (2 in.) dia.
  • Features: Lead Shielding - Compatible with 5.1 cm (2 in.) and 6.6 cm (2.6 in.) OD detectors, including:
    • Model 43-2
    • Model 43-2-2
    • Model 44-1
    • Model 44-2
    • Model 44-3
    • Model 44-10
    • Model 44-11
    • Model 44-17
    • Model 44-21
    • Model 44-98
Model 180-12
Shielded Sample Holder
  • Max. Sample Size: 5.8 x 2.97 cm (2.3 x 1.17 in.) [D x L]
  • Lead Shielding: Compatible with: Model 44-10, Model 44-11, Model 44-17
Model 180-28
Sample Holder for Model 26-Series Friskers
  • Max. Sample Size: 5.1 cm (2 in.) dia.
  • Features: Compatible with Model 26-Series