- Home
- All Products
- Model 3030
Model 3030
The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS(Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. This combined system supplies independent backlit LCD readouts to support discriminated alpha and beta sample counting. Key features include background subtraction, crosstalk correction, separate alpha/beta alarms, cpm/dpm operating modes, and a pre-scripted QC function with automatic reminder timer.
Features
- Fully Integrated Alpha-Beta Sample Counter
- Simultaneous Alpha and Beta Counting
- Shielded 5.1 cm (2 in.) Diameter Sample Tray
- Independent Readouts
- CPM & DPM Modes
- Background Subtraction
- Alpha/Beta Alarms
- QC Check
- 8 Hour Battery Operation
- Real Time Clock
- RS-232 Interface
- Includes PC Software
Related Products
Model 14C-MERK
Medical Environment Response Kit
- Model 14C Survey Meter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Model 25 Series Personal Radiation Monitor
- Check Source and Holder
- Rugged Case
Model 2241-3MERK
Medical Environment Response Kit
- Model 2241-3 Scaler-Ratemeter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Model 44-142 Beta Scintillator Detector
- Model 25 Series Personal Radiation Monitor
- Check Source and Holder
- Rugged Case
Model 3001-MERK
Medical Environment Response Kit
- Model 3001 Survey Meter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Model 44-142 Beta Scintillator Detector
- Model 25 Series Personal Radiation Monitor
- Check Source
- Rugged Case
Model 14C-RK
Emergency Response Kit
- Model 14C Survey Meter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Check Source and Holder
- Rugged Case
Model 3002/FM Series
Alpha-Beta Floor Monitor
- Alpha-Beta Scintillation Detectors
- Active Window Area: 400 or 1080 cm2 (62 or 167.4 in2)
- 22.4, 40.9, or 65.7 cm (8.8, 16.1, or 25.9 in.) Wide Detection Path
- Adjustable Detector Height
Model 42-38
WENDI-2 Wide Energy Neutron Detector
- Detector Type:
- 3He Tube
- Moderator: 22.9 cm (9 in.) dia.
- Sensitivity (241Am/Be): 450 cpm per mrem/hr
- Detection Range: Thermal to 5 GeV
Model 78-6
Stretch Scope Survey Meter
- Analog + Digital Meter
- Extends to 3.6 m (12 ft.)
- NaI(Tl) Scintillator Detector
- Range: 0.01 to 50 µSv/h (1 to 5000 µR/hr)
Model 79/2
Stretch Scope Survey Meter
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- Internal Energy-Compensated GM
- Range: 0.001 mSv/h to 0.04 Sv/h (0.1 mR/hr to 4 R/hr)
Model 79/1
Stretch Scope Survey Meter
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- CsI(Tl) Scintillator Detector
- Range: 0.01 µSv/h to 500 µSv/h (1 µR/hr to 50 mR/hr)
Model 79
Stretch Scope Survey Meter
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- Energy-Compensated GM Detector
- Range: 10 µSv/h to 10 Sv/h (1 mR/hr to 1000 R/hr)