Model 120
Alpha-Beta-Gamma Sample Counter
  • Detector Type: Alpha-Beta ZnS(Ag) + Plastic Scintillator
  • Max. Sample Size: 5.1 x 1.0 cm (2 x 0.4 in.) [D x L] Adapted for iCam Filters
  • Efficiency: 239Pu : 40%
Request a quote
Model 44-110-4
Windowless Sample Counter Detector
  • Detector Type: Alpha-Beta Windowless Gas Flow Proportional
  • Max. Sample Size: 5.1 x 0.9 cm (2.0 x 0.4 in.) [D x L]
  • Efficiency:
    • 3H : 3%
    • 14C : 21%
    • 63Ni : 36%
    • 239Pu : 42%
Request a quote
Model 43-78-2
Alpha-Beta Sample Counter Head for iCam/Harwell Filters
  • Detector Type: Alpha-Beta ZnS(Ag) + Plastic Scintillator
  • Max. Sample Size: 5.1 x 1.0 cm (2 x 0.4 in.) [D x L] Adapted for iCam Filters
  • Efficiency: 239Pu : 40%
Request a quote
Model 43-10-10
Alpha-Beta Sample Counter Head for iCam/Harwell Filters
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
  • Efficiency:
    • 239Pu : 37%
    • 230Th : 32%
    • 238U : 39%
    • 14C : 5%
    • 99Tc : 27%
    • 137Cs : 29%
    • 99Sr/90Y : 26%
Request a quote
Model 43-10-1
Alpha Sample Counter Head
  • Alpha-Beta ZnS(Ag) + Plastic Scintillator
  • Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
  • Efficiency:
    • 239Pu : 37%
    • 230Th : 32%
    • 238U : 39%
    • 14C : 5%
    • 99Tc : 27%
    • 137Cs : 29%
    • 99Sr/90Y : 26%
Request a quote
Model 43-78
Alpha Sample Counter Head
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 12.7 x 0.46 cm (5 x 0.18 in.) [D x L]
  • Efficiency: 230Th : 37% 239Pu : 37%
Request a quote
Model 43-10
Alpha Sample Counter Head
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
  • Efficiency: 230Th : 37%
Request a quote
Model 43-9
Alpha Sample Counter Head
  • Detector Type: Alpha ZnS(Ag) Scintillator
  • Max. Sample Size: 2.5  x 0.15 cm (1 x 0.06 in.) [D x L]
  • Efficiency: 230Th : 30%
Request a quote
Model 133 Series
Gamma Detector
  • Detector Type: Energy-Compensated GM
  • Sensitivity (Cs-137):
    • 133-2: 1000 cpm per mR/hr
    • 133-3: 450 cpm per mR/hr
    • 133-4: 100 cpm per mR/hr
    • 133-6: 18 cpm per mR/hr
    • 133-7: 4.2 cpm per mR/hr
  • Linear Range
    • 133-2: 0.1 to 200 mR/hr
    • 133-3: 0.1 mR/hr to 1 R/hr
    • 133-4: 1 mR/hr to 2 R/hr
    • 133-6: 4 mR/hr to 6 R/hr
    • 133-7: 25 mR/hr to 30 R/hr
Request a quote
Model 44-10-5
Waterproof Gamma Scintillator Detector
  • Description: 
    • 5.1 x 5.1 cm (2 x 2 in.) NaI(Tl) Scintillator Stainless Steel Housing Hard-Wired 3 m (10 ft.) Cable
    • Submersible up to 30 m (100 ft)
  • Part Number: 47-2427
Request a quote
Model 44-2-23
Waterproof Gamma Scintillator Detector
  • Description: 
    • 2.5 x 2.5 cm (1 x 1 in.) NaI(Tl) Scintillator Aluminum Housing Hard-Wired 3 m (10 ft.) Cable
    • Submersible up to 30 m (100 ft)
  • Part Number: 47-3656
Request a quote
Model 44-2-14
Waterproof Gamma Scintillator Detector
  • Description: 
    • 2.5 x 2.5 cm (1 x 1 in.) NaI(Tl) Scintillator Aluminum Housing Hard-Wired 3 m (10 ft.) Cable
    • Submersible up to 30 m (100 ft)
  • Part Number: 47-2473
Request a quote
Model 9-7
Underwater Housing
  • Description:
    • Waterproof Housing for Model 9-7 Ion Chamber Detectors (Models 9-7-LD, 9-7-BM, 9-7-BH)
    • Hard-Wired 18.3 m (60 ft.) or 30 m (100 ft.) Cable
  • Part Number:
    • 4536-046 (60 ft. cable)
    • 4536-047 (100 ft. cable)
Request a quote
Model 42-38
WENDI-2 Wide Energy Neutron Detector
  • Detector Type:
    • 3He Tube
    • Moderator: 22.9 cm (9 in.) dia.
  • Sensitivity (241Am/Be): 450 cpm per mrem/hr
  • Detection Range: Thermal to 5 GeV
Request a quote
Model 42-41L
Neutron Detector
  • Detector Type: PRESCILA Proton Recoil Scintillator
  • Sensitivity (241Am/Be): 350 cpm per mrem/hr
  • Detection Range: Thermal to 100 MeV